HBS86 Schrittmotor-Regler 0-8,2 A, mit Gerberrückführung,
Eingangsspannung 20-80 VDC, Maximale Schrittfrequenz 200Khz
32-bit DSP based vector control algorithm to combine advantage of open-loop
stepper brushless servo drives
Default maximum 200K frequency; 500K optional
Input voltage:
20-80 VDC
Load-based automatically adjusted output current of
0-8.2A
Default 4,000 (1/20) microstepping resolution; 200-104,000 (increase by 200) software configurable
No Stall and no loss of step. Closed loop between the drive and driven motor to eliminate
loss of move synchronization in open loop stepper systems.
Smooth motor movement; extra low motor heating
Fast response, no delay and zero settling time
High torque at starting and low-middle speed; high stiffness at standstill
No tuning for easy configuration over traditional servo systems
No overshooting; no hunting over traditional servo systems
Much lower cost than traditional servo systems
Specification
Model: |
HBS86 |
Phase: |
2 |
Control Mode: |
Step & Direction |
Max Input Frequency: |
200KHz |
Encoder Feedback: |
Yes. Fully close the loop between the drive and drive motor |
Input Voltage Range: |
20 - 80 VDC |
Peak Current: |
8.20 A |
Software Cofig Resolution Range: |
200 - 102,400 (increased by 200) |
of DIP Switch Resolution Config.: |
15 |
DIP Switch Resolution Setings: |
800, 1600, 3200, 6400, 12800, 25600, 51200,
1000, 2000, 4000, 5000, 8000, 10000, 20000, 40000 |
Default Holding Current Percentage: |
40 % |
Communication Type: |
RS232 |
Pulse enabled at: |
Rising edge |
Isolation Resistance: |
500M Ohm |
Environment: |
Avoid dust, oil fog and corrosive gases |
Ambient Temporature: |
0-50°C |
Humidity: |
40–95% RH |
Operating Temporature: |
0-70°C |
Vibration: |
5.9 m/s2 Max |
Storage Temporature: |
-20-65°C |
Specification: |
5.94 X 3.65 X 2.05 Inches |
Weight: |
1.26 lbs |
Mechanical Specification
Unit: mm
1 inch = 25.4 mm
Typical Connection